| DRAINAGE OPTIONS |
DELTA SUMPS + PUMPS |
|
|

Delta Retrofit
sumps are fitted with a dual pump system and have
three 110mm side inlets to take ground water, and grey water
from shower, laundry and sink waste |
|
| |
When specifying a sealed
cavity membrane system, full consideration must be given to drainage,
when installed below ground.
 The
concept of the drained cavity system is to collect and manage
any moisture which breaches the integrity of the structure by
channeling, collecting, and discharging such free water via a
suitable evacuation point."
Channels, laid to a nominal fall, can discharge passively into a sump
or be connected to a drainage system but access for maintenance should
be provided. |
 |
Access ports allow
inspection and water jetting of channels, while sumps have a sealed
access cover which allows for annual maintenance checks to be carried
out, which are recommended.
If drainage has been installed, it should be flood tested before covering
it up to make sure the system works.
Delta offer a choice of sump+pump stations to
fit the purpose, and free advice is available from their technical
staff. |
 |
| DELTA -AQUADUCT |
DELTA CHANNEL |
|
|
|
|
Delta Aquaduct is a drainage channel which acts
as a perimeter conduit bedded in at the floor/wall angle. Where
appropriate, it can be laid under the slab to take off ground water
to a sump or soak away, and reduce flotation pressures from baring
on the slab.
Delta Aquaduct is fully perforated for maximum performance,
and incorporates an outer geotextile filter to prevent particles
|
 |
From entering the channel. The
product comes on a roll 150m x 60mm diameter. It is also available
in 100m x 100mm dia rolls.
Delta Channel is a water collection conduit
which is bedded into a preformed channel at the floor/wall angle.
Holes in the channel wa  ll
allows water to ingress at this point to drain away to a sump
or soak away. Access ports are available to allow maintenance
and inspection. |
|
| POWER FAILURE? |
HELP IS AT HAND |
|
|
|
|
If you've installed a cavity drained
system internally, one of the main design considerations is how are
you going to manage the water collection and discharge. This can
be done passively into existing drainage points, if available and
appropriate.
However, the majority of projects require a collection sump + pump, to
automatically manage the evacuation of any water ingress. This type of
unit requires mains power to operate, so what can be done if the power
fails, and is coincident with high water ingress? Here are two options
from Delta. |
|
High water level alarm -
This system gives an audible warning if a high level situation occurs.
It is fitted with it's own rechargeable battery, which is trickle
charged , and will still operate in the event of mains power failure.
Delta Power-Pack -This unit is designed to run
the pumps if a power failure occurs. The unit is trickle charged
under normal conditions, and will auto switch to battery power
if mains power fails. The unit will pump approx. 8,910 litres
in back up mode but this can be upgraded by adding up to ten
extra power units. Adding one unit raises the capacity to 26,730
litres. |
|

Delta Power Pack
Pumps 8,910 Ltr in back up mode

|