| DRAINAGE OPTIONS |
DELTA SUMPS + PUMPS |
|
|

Delta
Retrofit sumps are fitted with a dual pump system
and have three 110mm side inlets to take ground water,
and grey water from shower, laundry and sink waste |
|
|
When specifying a sealed cavity
membrane system, full consideration must be given to drainage,
when installed below ground.
 The concept of the drained cavity system is to collect and manage
any moisture which breaches the integrity of the structure by channeling,
collecting, and discharging such free water via a suitable evacuation
point."
Channels, laid to a nominal fall, can discharge passively into a
sump or be connected to a drainage system but access for maintenance
should be provided. |
|
Access ports allow inspection and water jetting of channels, while sumps have a sealed access cover which allows for annual maintenance checks to be carried out, which are recommended.
If drainage has been installed, it should be flood tested before covering it up to make sure the system works.
Delta offer a choice of sump+pump stations to fit the purpose, and free advice is available from their technical staff. |
|
| DELTA -AQUADUCT |
DELTA CHANNEL |
|
|
|
|
Delta Aquaduct is a drainage channel which acts as
a perimeter conduit bedded in at the floor/wall angle. Where appropriate,
it can be laid under the slab to take off ground water to a sump
or soak away, and reduce flotation pressures from baring on the slab.
Delta Aquaduct is fully perforated for maximum performance, and incorporates
an outer geotextile filter to prevent particles
|
 |
From entering the channel. The product comes on a roll 150m x 60mm diameter. It is also available in 100m x 100mm dia rolls.
Delta Channel is a water collection conduit which
is bedded into a preformed channel at the floor/wall angle. Holes
in the channel wa  ll allows water to ingress at this point to drain
away to a sump or soak away. Access ports are available to allow
maintenance and inspection. |
 |
| POWER FAILURE? |
HELP IS AT HAND |
|
|
|
If you've installed a cavity drained system internally,
one of the main design considerations is how are you going to manage
the water collection and discharge. This can be done passively into
existing drainage points, if available and appropriate.
However, the majority of projects require a collection sump + pump,
to automatically manage the evacuation of any water ingress. This
type of unit requires mains power to operate, so what can be done
if the power fails, and is coincident with high water ingress? Here
are two options from Delta. |
 |
High water level alarm - This system gives an audible warning if a high level situation occurs. It is fitted with it's own rechargeable battery, which is trickle charged , and will still operate in the event of mains power failure.
Delta Power-Pack -This unit is designed to run
the pumps if a power failure occurs. The unit is trickle charged
under normal conditions, and will auto switch to battery power
if mains power fails. The unit will pump approx. 8,910 litres in
back up mode but this can be upgraded by adding up to ten extra
power units. Adding one unit raises the capacity to 27,300 litres. |
|

Delta Power Pack
Pumps 8,910 Ltr in back up mode

|